First, because the multi-layer soft and hard stack seals are fixed on the valve plate, when the valve plate is always open, the media forms a frontal flush against its sealing surface, and after the soft seal tape in the metal plate interlayer is washed, it directly affects the sealing performance.

Second, subject to structural constraints The structure is not adapted to the following diameter DN200 valves, because the overall structure of the valve plate is too thick, large flow resistance.

Third, due to the principle of triple eccentric structure, the seal between the sealing surface of the valve plate and the valve seat is to press the valve plate against the valve seat by the torque of the transmission device. In the normal flow state, the higher the medium pressure, the tighter the seal extrusion. When the medium of the flow passage is reversed, the seal begins to leak when the positive pressure between the valve plate and the valve seat is smaller than the pressure of the medium as the pressure of the medium increases.